NXP Semiconductors /LPC5410x /VFIFO /STATUSART0

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as STATUSART0

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (RXTH)RXTH 0 (TXTH)TXTH 0RESERVED 0 (RXTIMEOUT)RXTIMEOUT 0RESERVED 0 (BUSERR)BUSERR 0 (RXEMPTY)RXEMPTY 0 (TXEMPTY)TXEMPTY 0RESERVED0RXCOUNT0TXCOUNT

Description

USART0 status

Fields

RXTH

Receive FIFO Threshold. When 1, the receive FIFO threshold has been reached. This is a read-only bit.

TXTH

Transmit FIFO Threshold. When 1, the transmit FIFO threshold has been reached. This is a read-only bit.

RESERVED

Reserved. Read value is undefined, only zero should be written.

RXTIMEOUT

Receive FIFO Timeout. When 1, the receive FIFO has timed out, based on the timeout configuration in the CFGUSART register. The timeout condition can be cleared by writing a 1 to this bit, by enabling or disabling the timeout interrupt, or by writing a 1 to the timeout interrupt enable.

RESERVED

Reserved. Read value is undefined, only zero should be written.

BUSERR

Bus Error. When 1, a bus error has occurred while processing data for USARTn. The bus error flag can be cleared by writing a 1 to this bit.

RXEMPTY

Receive FIFO Empty. When 1, the receive FIFO is currently empty. This is a read-only bit.

TXEMPTY

Transmit FIFO Empty. When 1, the transmit FIFO is currently empty. This is a read-only bit.

RESERVED

Reserved. Read value is undefined, only zero should be written.

RXCOUNT

Receive FIFO Count. Indicates how many entries may be read from the receive FIFO. 0 = FIFO empty. This is a read-only field.

TXCOUNT

Transmit FIFO Count. Indicates how many entries may be written to the transmit FIFO. 0 = FIFO full. This is a read-only field that is valid only when the TxFIFO is fully configured and enabled.